How Do You Know if Your Building Need Fire Alarm?

commercial fire alarm systems

Commercial Fire Alert Systems

Well-nigh commercial buildings require a burn down alarm system according to the NFPA (National Burn Protection Association Codes) and IBC (International Building Lawmaking). If you are looking for data every bit to whether your new or existing commercial building requires a commercial burn alarm arrangement, see below for guidelines for different types of facilities. To ensure you lot are inside code for your location, you'll as well need to refer to your state, county and municipal fire code requirements.

IBC Requirements for Commercial Fire Warning Systems

The International Building Code outlines the types of facilities that require a fire alarm arrangement in department 907. The IBC states, "An canonical fire alert system installed in accord with the provisions of this lawmaking and NFPA 72 shall be provided in new buildings and structures in accordance with Sections 907.two.21 through 907.ii.23."

These are the types of commercial buildings listed in Section 907.2 with requirements for new facilities.

Offices & Service Providers (Group B)

Offices and service providers are categorized under Group B in both the International Edifice Code and the Florida Building Code. If you lot are a service provider, your business most likely falls under Group B. Delight note that storing records and accounts also falls under Grouping B.

Group B building occupants must have a manual burn down alarm system or an automatic sprinkler & notification arrangement if one or more of the following is truthful:

  1. The combined Group B occupant load of all floors is 500 or more
  2. The Grouping B occupant load is more than 100 persons above or below the lowest level of go out belch.
  3. The burn expanse contains an ambulatory care facility.

Based on the IBC, if you are in a small, standalone role building, you lot may not need a fire alarm system, but check with your local authorities.

Businesses in this category include, but are not limited to:

  • Airdrome traffic control towers
  • Ambulatory care facilities
  • Animate being hospitals, kennels and pounds
  • Banks
  • Barber and beauty shops
  • Car wash
  • Borough assistants
  • Dispensary, outpatient
  • Dry cleaning and laundries: selection-up and commitment stations and cocky-service
  • Electronic data processing
  • Laboratories: testing and enquiry
  • Motor vehicle showrooms
  • Post offices
  • Impress shops
  • Professional services (architects, attorneys, dentists, physicians, engineers, etc.)
  • Radio and television stations
  • Phone exchanges
  • Training and skill evolution not in a school or academic program

commercial fire alarm systems

Retail Stores (Grouping 1000)

Retail stores have similar requirements for burn down warning systems. Retail and merchandising facilities must install a fire alarm system if one or more of the following is truthful:

  1. The combined Group G occupant load of all floors is 500 or more persons.
  2. The Group Yard occupant load is more than 100 persons to a higher place or below the lowest level of exit discharge.

Group G facilities include but are not limited to:

  • Department stores
  • Drug stores
  • Markets
  • Greenhouses for display and sale of plants that provide public access
  • Motor fuel dispensing facilities
  • Retail or wholesale stores
  • Sales rooms

Places of Assembly (Grouping A)

Places of assembly of l or more than people are classified in occupant group A. These buildings crave a manual or automated fire warning system if one of the following is true:

  1. The occupant load due to the assembly occupancy is 300 or more
  2. The Group A occupant load is more 100 persons above or below the everyman level of leave discharge

Group A facilities include but are non limited to:

  • Places of religious worship
  • Picture show theaters
  • Concert halls
  • Theaters
  • Banquet halls
  • Casinos
  • Nightclubs
  • Restaurants & dining facilities
  • Taverns & bars
  • Amusement arcades
  • Bowling allies
  • Courtrooms
  • Libraries
  • Museums
  • Art galleries
  • Funeral parlors
  • Gymnasiums
  • Indoor swimming pools
  • Stadiums

Other Commercial Facilities

Other commercial facilities that require fire warning systems depending on occupancy are the following:

  • Group E (Schools & Educational Facilities)
  • Group F (Low Hazard Manufacturing plant Industrial Facilities)
  • Group H (High Chance Manufacturing Facilities)
  • Group I (Institutional Facilities Including Healthcare, Corrections & Daycare)
  • Group R (Residential Facilities Including Hotels & Dormitories)
  • Grouping S (Storage Facilities)

We'll encompass these facilities and requirements in detail in a futurity article.

Commercial Fire Alarm System Requirements in Florida

Most state and municipal fire codes are adjusted from the IBC, the NFPA and the International Burn down Codes. Bank check your land building code for any amendments that outline different requirements in your land.

You tin can check the Florida Building Code for amendments to your specific manufacture hither:

Florida Building Code Fire Protection Systems

Fire Warning Organisation Testing, Inspection & Maintenance

Palmer Electrical provides Commercial Fire Alarm Systems installation for new and existing facilities. Nosotros are besides a provider of UL Listed Central Station Burn down Alarm Monitoring to continue your facility safety 24/7/365. Palmer Electrical has served commercial facilities in Central Florida for over 70 years. Turn to the fire warning installation & monitoring company that Orlando businesses trust. Contact us today for a costless quote at 407-646-8700.

  • Burn Warning Systems & Maintenance
  • Security Organisation Services
  • Emergency Electrical Services